contact us

contact-email
contact-logo

REPSUN  LIGHTNING PROTECTION CO., LIMITED

We provide customers with quality products and provide high-quality services.

看不清,请点击我!

If you would like to leave us a comment please go to contact us

contact-clo

Surge Protectors for AC Power Supply System (T2)

Integrated fuse surge protector with pluggable design, applied in TT/TN system
Surge Protectors for AC Power Supply System (T2) 02
Surge Protectors for AC Power Supply System (T2) 03
Surge Protectors for AC Power Supply System (T2) 04
Surge Protectors for AC Power Supply System (T2) 04

PRODUCTS DETAIL

Product Picture

Surge Protectors for AC Power Supply System (T2) 06

(L-N/PE)
(N-PE)

Surge Protectors for AC Power Supply System (T2) 07

(1+1)
(2+0)

Surge Protectors for AC Power Supply System (T2) 08

(3+0)

Surge Protectors for AC Power Supply System (T2) 09

(3+1)
(4+0)

Surge Protectors for AC Power Supply System (T2) 10

(6+1)
(7+0)

Surge Protectors for AC Power Supply System (T2) 11

Dimension drawing(mm)1P

Surge Protectors for AC Power Supply System (T2) 12

Basic circuit diagram

Features

Type2 surge protector comply with IEC 61643-11;

Low voltage protection level;

Reliable supervision due to double integrated disconnection devices; 

Optional to use without a fuse;

Remote alarm terminal optional.

Datasheet

Type

REP-MP20T2-XXX-XS

The SPD according to IEC 61643

II/T2

Maximum continuous voltage Uc [L-N]

440Vac

385Vac 320Vac 275Vac 150Vac

Maximum continuous voltage Uc [N-PE]

255Vac

Nominal discharge current(8/20ps)ln

20kA

Maximum discharge current(8/20ps)lmax

40kA

Voltage protection level Up [L-N]

≤2.0kV

≤1.8kV ≤1.5kV ≤1.2kV ≤1.1kV

Voltage protection level Up [N-PE]

<1.8kV

Response time

25ns[L-N/PE]/100ns[N-PE]

Operating temperature range

-40°C~+80°C

The minimum cross-sectional area of installation

1.5mm² solid/flexible

The maximum cross-sectional area of installation

25mm² solid/flexible

Remote alarm contact

Remote alarm contact optional

Degree of protection

IP20

Failure indication

Green: Normal ; Red: Failure

Enclosure material

Thermoplastic; extinguishing degree UL94-V0

Technical feature

Double integrated disconnection devices with double protections

 

Request A Quote

refresh!

Related Products

Surge Protectors for AC Power Supply System (T2)

Surge Protectors for AC Power Supply System (T2)

Surge Protectors for AC Power Supply System(T2)

Surge Protectors for AC Power Supply System(T2)

Surge Protectors for AC Power Supply System(T2)

T2-MP40.60

Power Surge Protector (Class C / Type 2)

   